Description
Optimized Thermal Regulation: The direct acting mechanism ensures immediate response to temperature fluctuations between 160°F and 205°F
Built to strictly manage LRA (Locked Rotor Amps) during the initial startup phase
Simplified Installation: Standard spade terminal configuration allows for rapid swap-outs during service calls
As an OEM Daikin replacement part
Integrated Auxiliaries: Features factory-installed 1NO and 1NC contacts for immediate signaling and interlocking
Fenwal 35-605611-103 Control L99H008 Optimized Thermal Regulation: The directThe Fenwal 35 605611 103 is a direct spark ignition (DSI) control module designed for precise gas burner sequencing in commercial and residential heating applications. Operating on a 24VAC 50 60Hz power supply, this microprocessor based controller manages the gas valve, monitors flame sensing, and executes safety lockdowns. It features a 15 second pre purge (PP) cycle to clear residual gases and a 7 second trial for ignition (TFI) period. The unit is